20 SEED TESTING INTERNATIONAL www.seedtest.org ASSOCIATION NEWS The overall performance of the nine laboratories reporting specific items is shown in Table 1. The table shows, for each item of the checklist, the number of occurrences of the different evaluations; additionally, the incidence rate for the ‘OK’ score is reported in brackets, based on the total number of applicable and non-optional cases. Some non-conformities were detected in the general section, but since they are not specific to GMO testing, they are not discussed in detail here. A low rate of compliance with the ISTA Rules was detected when reporting the testing objectives (adventitious presence vs trait purity; assessment of presence and/or estimation of level) and the testing approach (qualitative vs quantitative assay on groups or bulks). These are basic definitions that clearly and synthetically define the scope of testing and that should always be used. The testing plan (number of groups/bulks, number of flour subsamples per group or bulk, number of replicate measurements per flour subsample) was often not sufficiently described, and this is also related to the inadequate definition of the testing approach mentioned above. A satisfactory level of compliance was found instead when defining the testing technology (end-point PCR, real-time PCR, LAMP; all reporting laboratories used DNA-based assays) and the type (pure seed, washed, etc.) and size (number of seeds) of the working sample. On the other hand, the testing targets were rarely reported in compliance with the List of Standardised Terms[5] adopted by ISTA (based on the Biosafety Clearing House and Euginius databases). Reporting of the Limit of Detection was often incomplete, lacking the specification of the unit of measurement, whereas for the Limit of Quantification no conclusions can be drawn since only two laboratories applied quantitative assays. The description of reference materials was often inadequate. Regarding the section concerning the reporting of results, the assessment of presence was reported correctly most of the time, whereas the estimation of level was reported correctly only half of the time, including the associated confidence intervals. When looking at the compliance of individual laboratories in completing the 14 technical items (Table 2), only three (laboratories 4, 5 and 6) reached a satisfactory level of correctly reported items (≥67 %), with zero or one missing. Three laboratories (1, 3 and 8) reached an intermediate level (compliance between 38 and 56 %), whereas for the other three (laboratories 2, 7 and 9) the compliance was insufficient (≤30 %). Of the two non-accredited laboratories, one obtained the lowest score, while the other was positioned at the intermediate level. Conclusions Even though this first experiment involved a small number of laboratories, it was very useful since it allowed us to identify several issues in reporting GMO testing on ISTA Certificates. The conclusions that can be drawn from this experiment are important for the full implementation of ISTA accreditation based on the PBA. While the ISTA system has the potential to provide clarity and uniformity for reporting GMO testing results, laboratories must put it into practice. The results suggest the following actions to support laboratories and improve uniformity in reporting: • Preliminary proposals for amendments to the ISTA Rules. These should concern improving clarity in section 19.7 (Reporting results), adding a definition of ‘testing plan’, and harmonising instructions for its reporting in 19.7.1, 19.7.2 and 19.7.3. • Based on the checklist developed in this exercise, a list of text examples demonstrating how each aspect should be correctly reported will be compiled. This list will represent a useful guide for OIC completion exercises and, more importantly, for issuing real OICs. Once consolidated, an example on how to report the GMO results will be implemented in the ISTA Certificate Learning Tool (www.learn-ista.org) as already existing for other aspects of seed testing. • Since reporting the results of GMO testing is crucial but also revealed to be rather complex, participation in the OIC completion exercise in future PTs on GMO will be strongly encouraged, even if participants will not be rated. • The ISTA Accreditation and Technical Department intends to implement a system for the preparation of evaluation reports in the GMO PT database at the ISTA Secretariat. References [1] Principles and conditions for laboratory accreditation under the Performance Based Approach. Available at: www.seedtest.org/api/rm/TF6EX97X4A3P85W/ acc-d-04-accreditationunderpbav3-0.pdf. [2] Performance Data Evaluation for the presence of seed with specified trait(s) in seed lots. Available at: www.seedtest.org/api/rm/GF84XM5G6Y24M9Q/ acc-d-05-performancedataevaluation- 1seedlots-v2-1.pdf. [3] Performance Data Evaluation for Specified Trait Purity. Available at: www.seedtest. org/api/rm/NJ628M8Z936QN27/acc-d-05- performancedataevaluation-2purity-v1-1.pdf. [4] ISTA (2026). International Rules for Seed Testing. International Seed Testing Association, Wallisellen, Switzerland. [5] Standardised GMO Terms. Available at: www.seedtest.org/en/technical-committees/ gmo-committee.html. Laboratory GMO accreditation OK* Missing Incomplete Inaccurate Incorrect Optional Not applicable Total 1 Yes 5 38 % 3 2 2 1 1 14 2 No 1 8 % 7 1 2 2 1 14 3 Yes 5 56 % 2 1 1 5 14 4 Yes 8 67 % 1 2 1 2 14 5 Yes 8 80 % 1 1 1 3 14 6 Yes 8 80 % 1 1 1 3 14 7 Yes 2 22 % 4 1 1 1 5 14 8 No 5 42 % 4 2 1 2 14 9 Yes 3 30 % 4 1 1 1 4 14 Total 45 46 % 25 12 8 8 3 25 126 Table 2. Performance of individual laboratories in reporting genetically modified organism testing on Orange International Certificates in PT24 *Percentage based on number of applicable and non-optional items
View this content as a flipbook by clicking here.